2.9 Pump Temperature Testing
The pump shall be tested as described in para. 2.2(b), section 34 of UL 778. at the maximum duty cycle the pump will allow.
2.10 Wiring Harness Entrance and Location
The wiring harness and electrical controls not enclosed in the pump housing shall be located above the flood level rim of the tank or reservoir and above the drains or overflows.
2.11 Life Cycle Test
The electrical components and pump shall pass a 75,000 life cycle test. The test shall be performed on the waler closet at the maximum cycle rule the electronic controls will allow. Upon completion of the life cycle test, the average volume per flush shall not vamy more than 0.15 gal 0.57 l. or lO’. whichever is greater.
3 MARKING AND INSTRUCTION MANUAL
3.1 Marking
3.1.1 Water Closet. The water closet shall be legibly marked as specified in ASME Al 12.19.2M and other standards referenced in this Standard see punt. 1.3).
3.1.2 Pump. The pump shall have the following markings visible on it in its normal operating position and a second label visible on the exterior of the water closet or cord stating:
The word warning shall be a minimum of 2 2.4 mm high.
3.2 Instruction Manual
An instruction manual shall be provided that includes instructions for routine maintenance and operation.