ASME A112.19.16:2006 pdf download

ASME A112.19.16:2006 pdf download.Terrazzo Plumbing Fixtures.

3.1.2 Performance Requirements. The test samples that do not comply with the performance requirements as set forth in the applicable ANSI or CSA standard shall be cause for recction of the product.
3.2 SLip Resistance
3.2.1 Test Method. The surfaces of the bathing area of the shower receptor shall be slip resistant and shall comply with ASTM F 462.
3.2.2 Performance Requirements. The test samples that do not comply with the performance requirements as set forth in the ASTM standard shall be cause for rejection of the product.
3.3 Surface
3.3.1 Test Method. Terrazzo bathtubs, shower receptors, wash fountains, and lavatories/lavatory systems shall meet the requirements of IAPMO/ANSI Z124.12, IAPMO/ANSI Z124.3, IAPMO/ANSI Z124.6, or SA B45.5 for stain resistance, chemical resistance, wear and cleanahility, and thermal shock resistance.
3.3.2 Performance Requirements. The test samples that do not comply with the performance requirements as set forth in the applicable ANSI or CSA standard shall be cause for rejection of the product.
4 MARKING AND IDENTIFICATION
Each fixture shall be permanently marked with the manufacturer’s name or trademark. Acceptable means of applying permanent marking shall include fired-on, etching, stamping with permanent (nonwater-soluble) ink, and cast-in markings. Such marking shall be located where it can be seen after installation. Adhesive labels that comply with UL 969 shall also be considered permanent when installed on areas of the fixture that are not normally submerged in water. The exposure conditions for labels contained in para. 7.1 of UL 969 shall apply along with the additional exposure to the detergent test specified in Table 7.4 of UL 969.
Each fixture shall be supplied with written care and maintenance instruct ions, including sealing recommendations and installation instructions.